Using SNMP Monitoring

Prev Next

You can configure the CTERA Edge Filer for monitoring using SNMP. This enables you to gather a wide range of information about the devices.

SNMP can be used with all CTERA Edge Filers. SNMP v1, v2c, and v3 are supported.

CTERA Edge Filer includes Net-SNMP. For details, refer to http://www.net-snmp.org.

Information is collected for the following MIBS:

The MIB files are available from the CTERA Knowledge base download center under Third-Party Products: SNMP MIBs.
The MIBs are stored on the SNMP server on the CTERA Edge Filer. You can monitor the CTERA Edge Filer MIBs using a management tool, such as the tool from https://www.paessler.com/.

Setting Up SNMP Monitoring on the CTERA Edge Filer

To set up SNMP monitoring:

  1. In the Configuration view, select System > SNMP in the navigation pane.
    The SNMP page is displayed.
    Image
  2. Slide Enable SNMP on.
    Image
  3. Configure the following settings:
    SNMP Port – The default is TCP 161.
    Note

    SNMP Engine ID is defined automatically based on the MAC address and cannot be changed.

    Read Community – Configure as Read-Only. The SNMP Read-Only Community String is like a password. It is sent along with each SNMP Get-Request and allows or denies access to the device.
  4. If you are using SNMP v3, slide Enable SNMPv3 on.
    Image
    • Enter a user name, authentication password, and the privacy password, which must be a minimum of 8 characters.
  5. If you made any changes, either click Save or click Revert to revert to the last saved configuration.