Edge Filer 7.13.6000.29
CTERA Edge Filer version 7.13.x was first released with version 7.13.6000.3 and included new features, which are described in What’s New in CTERA Edge Filer Version 7.13.x.
Upgrading a CTERA Edge Filer from an Earlier 7.x Version
CTERA recommends that you only upgrade to a new version from an immediate previous version. If you have an older version, upgrade in steps, first to an intermediate previous version and then to the new version. For example, to upgrade from 7.11.x to 7.13.x, first upgrade to 7.12.x and only then to this version.
After upgrading the edge filer, downgrading the edge filer is not possible.
Upgrading the software of an edge filer running an earlier 7.x version can be performed automatically when the edge filer is connected to a CTERA Portal and the latest edge filer firmware TGZ file is uploaded to the portal.
Resolved Issues
| ID Number | Description |
|---|---|
| APP-31203 | Improved security, including resolving CVE-2026-98432. |
Known Issues
| ID Number | Description |
|---|---|
| APP-28061 | Read only and Read/Write permissions follow the Samba convention of using the less strict permission. Workaround: Make sure all users that have the read only permission are in a group that only has a read only permission and not in a group that has read/write permission. |
Edge Filer 7.12.5400.30
CTERA Edge Filer version 7.12.x was first released with version 7.12.5400.5 and included new features, which are described in What’s New in CTERA Edge Filer Version 7.12.x.
Upgrading a CTERA Edge Filer from an Earlier 7.x Version
CTERA recommends that you only upgrade to a new version from an immediate previous version. If you have an older version, upgrade in steps, first to an intermediate previous version and then to the new version. For example, to upgrade from 7.11.x to 7.13.x, first upgrade to 7.12.x and only then to this version.
After upgrading the edge filer, downgrading the edge filer is not possible.
Upgrading the software of an edge filer running an earlier 7.x version can be performed automatically when the edge filer is connected to a CTERA Portal and the latest edge filer firmware TGZ file is uploaded to the portal.
Resolved Issues
| ID Number | Description |
|---|---|
| APP-31204 | Improved security, including resolving CVE-2026-98432. |
Known Issues
| ID Number | Description |
|---|---|
| APP-28061 | Read only and Read/Write permissions follow the Samba convention of using the less strict permission. Workaround: Make sure all users that have the read only permission are in a group that only has a read only permission and not in a group that has read/write permission. |
| APP-28193 | The last cloud share in the Shares page is displayed OFFLINE, even though it is online. |
Edge Filer 7.11.5100.40
CTERA Edge Filer version 7.11.x was first released with version 7.11.4900.3 and included new features, which are described in What’s New in CTERA Edge Filer Version 7.11.x.
Upgrading a CTERA Edge Filer
Upgrading the software of an edge filer running an earlier 7.x version can be performed automatically when the edge filer is connected to a CTERA Portal and the latest edge filer firmware TGZ file is uploaded to the portal.
After upgrading the edge filer, downgrading the edge filer is not possible.
Resolved Issues
| ID Number | Description |
|---|---|
| APP-31204, APP-29744 | Improved security, including resolving CVE-2026-98432 and CVE-2026-46333. |
Known Issues
| ID Number | Description |
|---|---|
| APP-29156 | N/A is displayed for the file count in the Cloud box in the Cloud Drive page. |